LED Transformer AC/DC 100W | Constant Voltage 24V 4.2A - TILLUME
LED Transformer AC/DC 100W | Constant Voltage 24V 4.2A - TILLUME
DALI Tunable White LED Power Supply AC/DC 240W | Constant Voltage 24V DT8 10A - TILLUME

Alimentation LED AC/DC 100 W | Tension constante 24 V 4, 2 A

Item Code: 85012M04 / Series: HLG

€47,96 EUR €31,99 EUR SAVE 33%

Tax included, Free Shipping (8-15days)

When using constant voltage LED, the voltage drop caused by line loss is inevitable. In order to reduce the problem of inconsistent LED brightness caused by line loss, this LED power supply supports adjustable output voltage to compensate for the voltage drop caused by line loss.

-23~27V Adjustment By User
-BuiIt- in active PFC function, PF>0.95
-No Ioad power consumption <0.15W
-Protections:Short circuit/Over load/Over voltage
-Fully encapsulated with IP65 level
-Suitable for LED lighting and moving sign applications
-l00% full load burn in test
-H05RN VDE Wires
-Low cost high reliability
-5 years warranty

Tips: NA

Description

100 W Alimentation LED 24 V 4, 2 A pour Spot LED et bande

Caractéristique

Le transformateur TILLUME intègre un contrôleur de correction du facteur de puissance à découpage (TM PFC) et un contrôleur quasi-résonant (QR) . Les contrôleurs PFC offrent une solution économique pour optimiser le facteur de puissance. Les contrôleurs QR offrent un rendement supérieur et des interférences électromagnétiques plus faibles que les systèmes PWM traditionnels.

Transformateur TILLUME Offre une intégration avancée et des performances supérieures à celles des systèmes PFC/PWM conventionnels. Le contrôleur PFC TM intégré optimise le rendement de conversion de puissance en réduisant les coûts du système. La commutation intelligente du PFC, la détection de courant nul et les mécanismes de limitation de fréquence permettent d'obtenir un meilleur rendement quelles que soient les conditions de charge.

pilote de LED dispose de nombreuses fonctionnalités écologiques intégrées pour optimiser l'efficacité de la conversion d'énergie.  

Ce transformateur LED intègre également de multiples fonctions de protection, telles que la décharge X-CAP, la protection contre les coupures, le verrouillage en cas de sous-tension, la limitation du courant cycle par cycle (OCP) des niveaux PFC et QR, la protection contre les surtensions de sortie (OVP) des niveaux PFC et QR, et la protection en boucle ouverte (OLP) des niveaux PFC et QR. Il protège ainsi le système des dommages causés par des pannes occasionnelles.

données techniques

Sortir :

Tension continue : 24 V
Plage de réglage de la tension : 23-27, 3 V
Courant nominal : 4, 2A
Puissance nominale : 100 W
Ondulation et bruit (max. )  : 150 mVp-p
Tolérance de tension : ±3, 0%
Régulation de la ligne : ±0, 5%
Régulation de charge : ±1, 5%
Configuration, temps de montée : 500 ms, 80 ms 115 VCA / 230 VCA
Temps d'attente (typ. )  : 16 ms/230 VCA 16 ms/115 VCA

Contribution :

Plage de tension : 100 ~ 265 VCA
Gamme de fréquences : 47 ~ 63 Hz
Facteur de puissance : PF≧0, 98/115VAC, PF≧0, 96/230VAC à pleine charge
Distorsion harmonique totale : THD < 20 % (à charge = 100 % / 115 VCA, 230 VCA)
Efficacité (typ. )  : >91%
Courant alternatif : 0, 99 A / 115 VCA 0, 49 A / 230 VCA
Courant d'appel (typ. )  : DÉMARRAGE À FROID 60 A (durée de vie = 550 μs mesurée à 50 % de la tension de crête) à 230 V CA ; selon la norme NEMA 410
Courant de fuite : <0, 25 mA / 264 VCA
Consommation électrique à vide :  <0, 15 W

Protection :

Surintensité : 120~130% OCP nominal 5, 5A / Le mode Hiccup récupère automatiquement une fois la condition de défaut supprimée
Court-circuit : Mode hoquet, récupère automatiquement une fois la condition de défaut supprimée
Surtension : 28 ~ 29, 5 V Arrêter et verrouiller la tension de sortie, puis la remettre sous tension pour récupérer
Surchauffe :  Coupez la tension de sortie, puis remettez sous tension pour récupérer

Environnement :

Température de fonctionnement : Tcase=-40 ~ +70℃
Température max. du boîtier :  Tcase=+85℃
Humidité de fonctionnement :  20 ~ 95 % HR sans condensation
Température de stockage, humidité : -40 ~ +80℃, 10 ~ 95% HR
Coefficient de température : ±0, 03%/℃ (0 ~ 50℃)

Sécurité et CEM :

Normes de sécurité : EN61347-1, BS EN/EN61347-2-13 indépendant, EN62384, GB19510. 1, GB19510. 14, EAC TP TC 004, IP67 approuvé ; conception se réfère à EN60335-1
Tension de tenue : I/PO/P : 3, 75 kVCA
Résistance d'isolement :  Entrée/sortie/p : 100M Ohms / 500 V CC / 25 °C / 70 % HR
Émission CEM : Conformité aux normes BS EN/EN55015, BS EN/EN61000-3-2 Classe C (charge ≧ 60 %)  ; BS EN/EN61000-3-3 ; GB17743 et GB17625. 1, EAC TP TC 020
Immunité CEM : Conformité aux normes BS EN/EN61000-4-2, 3, 4, 5, 6, 8, 11 ; BS EN/EN61547, niveau industrie légère (immunité aux surtensions ligne-ligne 2 kV)  ; EAC TP TC 020

Les autres :

Dimensions : 226*67*40mm (L*W*H)
Emballage : 0, 77 kg

Cliquez sur l'image pour voir les spécifications

Technical Manual

TILLUME HLG-100W-24A LED Power Supply Test Report

1, Block Diagram

2, Performance Evaluation

This session presents the test results of HLG-100W-24A LED Power Supply up to date. Overall the power supply meets the design specification.

All data was measured at 1.5M AWG16 CABLE END

Performance Highlights

  • No load standby power: below 40mW @230V
  • Max Efficiency @ 100% Load: 90.00%@115VAC & 91.20%@230VAC

Characterization Results Summary

Test Item

Test Result

1.Input Characteristics
Standby Power at no Load 22mW
Average Efficiency( 230Vac, 100% Load) 91.20%
2. Output Characteristics
Line regulation 0.5%
Load regulation 1.5%
Ripple & Noise 100mV
Over Shoot 2.6% Max
Under Shoot 2.2% Max
Dynamic test ±360mV
3. Time Sequence
Set up time <350mS
Hold up time >25mS
Rise time <150mS
Fall time <15ms

Test Equipments

Item Brand Module
AC Source  EVERFINE DPS1005-V200
Digital Power Meter EVERFINE LT-101A
Electrical Load ITECH IT8512G+
Oscilloscope Tektronix MDO32
Thermal HIKVISION K20

2,1 Input Characteristics

2,1,1 Standby Power / PF / THD

 Table.1 Standby Power Without Load

Input Voltage Specification Standby Power(mW) Vo(V)
100Vac/60Hz 150mW 20mW 24.2
115Vac/60Hz 20mW 24.2
230Vac/50Hz 30mW 24.2
264Vac/50Hz 50mW 24.2

Table.2 PF and THD with Full load

Input Voltage Specification PF Specification THD(%)
100Vac/60Hz >0.95 0.99 <20% 9.3%
115Vac/60Hz 0.99 8.8%
230Vac/50Hz 0.97 12.4%
264Vac/50Hz 0.96 13.2%

 


2,1,2 Efficiency

 Table.3 Efficiency

Input Voltage 100% 75% 50% 25% Avg. Eff
115Vac/60Hz 90.0% 90.8% 90.2% 90.5% 90.37%
230Vac/50Hz 91.2% 90.5% 90.8% 90.5% 90.75%


2,2 Output Characteristics

2,2,1 Line Regulation @ Load Regulation

 Table.4 Line Regulation@l Load Regulation

Input Voltage No Load Half Load Full Load Specification
100Vac/60Hz 24.2V 24.1V 24.0V
115Vac/60Hz 24.2V 24.1V 24.0V
230Vac/50Hz 24.2V 24.1V 24.0V
264Vac/50Hz 24.2V 24.1V 24.0V
Line Regulation 0% 0.5%
Load Regulation 0.82% 1.5%


2,2,2 Ripple & Noise

 Table.5 Ripple & Noise

Input Voltage R&N (mV)
No Load Full Load Specification
100Vac/60Hz 23mV 87mV 100mV
115Vac/60Hz 23mV 72mV
230Vac/50Hz 22mV 46mV
264Vac/50Hz 22mV 46mV

2,2,3 Dynamic Test

The Dynamic Test with a low set at 10% load lasting for 10ms and high set at 100% load lasting for 10ms is added to the output. The ramp is set at 0.25A/us at transient.

 Table.6 Dynamic Test

Input Voltage
Output(mV) Specification
100Vac/60Hz
115Vac/60Hz
230Vac/50Hz
264Vac/50Hz


2,2,4 Time Sequence (Full load)

 Table.7 Time Sequence

Item Input voltage Meas.Data Specification
Set up time 230V/115V 73.6mS/340mS <500mS
Hold-up time 230V/115V 25.6mS/25.2mS >10mS
Rise Time 230V/115V 104.5mS/136.3ms <150mS
Fall Time 230V/115V 11.1mS/11.8mS  NA


2,3 Temperature Test

 Table.8 TemperatureTest

 The thermal test is under 30℃ ambiance after 4 hours full load runing with 230Vac input

Position Mark Description Value
BD1 P1 Bridge 64.7
Q1 P2 PFC MOS 65℃
Q2 P3 QR MOS 67.5℃
D1 P4 Didoe 66.1
T1 P5 PFC Transformer 50.3
CAP1 P6 Capacitor 51.1℃
T2 P7 QR Transformer 91℃
Q3 P8 Synchronous MOS 77
CAP2
P9 Capacitor 61.3
CAP3 P10 Capacitor 56.3

 

3, Protection Performance

3,1 Over Current Protection

Input Voltage OCP Trigger Current (A) Specification
100Vac/60Hz 5A 5A
115Vac/60Hz 5A
230Vac/50Hz 5.4A
264Vac/50Hz 5.4A

 3,2 Over Voltage Protection

Input Voltage Output OVP Trigger Voltage (V)
115Vac/60Hz 29.5V
230Vac/50Hz 29.3V