LED Transformer AC/DC 100W | Constant Voltage 24V 4.2A
Item Code: HLG-100W-24A / Series: HLG
Tax included, Free Shipping (8-15days)
Tips:
100W LED Power Supply 24V 4.2A For LED Spot and Strip
Feature
TILLUME transformer integrates a switching mode power factor correction (TM PFC) controller and a quasi-resonant controller (QR) controller. PFC controllers provide a cost-effective solution for optimizing power factor. QR controllers have higher efficiency and lower electromagnetic interference compared to traditional PWM systems,.
TILLUME transformer provides advanced integration and higher performance than conventional PFC/PWM systems. The built-in TM PFC controller optimizes power conversion efficiency by reducing system costs. The intelligent PFC switch on and off, zero current detection, and frequency limiting mechanisms can achieve better efficiency under any load condition.
LED driver has many built-in green features to optimize power conversion efficiency.
This LED transformer also integrates multiple protection functions, such as X-CAP discharge, break protection, under voltage lockout, PFC and QR level cycle by cycle current limiting (OCP), PFC and Q R level output over-voltage protection (OVP), PFC and Q R level open loop protection (OLP). Therefore, it can protect the system from damage caused by occasional failures.
Technical Data
Output:
DC Voltage: 24V
Voltage Adjust Range: 23-27.3V
Rated Current: 4.2A
Rated Power: 100W
Ripple& Noise (max.): 150mVp-p
Voltage Tolerance: ±3.0%
Line Regulation: ±0.5%
Load Regulation: ±1.5%
Setup, Rise Time: 500ms, 80ms 115VAC / 230VAC
Hold Up Time(Typ.): 16ms/230VAC 16ms/115VAC
Input:
Voltage Range: 100 ~ 265VAC
Frequency Range: 47 ~ 63Hz
Power Factor: PF≧0.98/115VAC, PF≧0.96/230VAC @Full load
Total Harmonic Distortion: THD< 20%(@load=100%/115VC,230VAC)
Efficiency(Typ.): >90%
AC Current: 0.95A / 115VAC 0.5A / 230VAC
Inrush Current(Typ.): COLD START 60A(twidth=550μs measured at 50% Ipeak) at 230VAC; Per NEMA 410
Leakage Current: <0.25mA / 264VAC
No load power consumption: <0.15W
Protection:
Over Current: 110~ 120% Rated OCP 5A / Hiccup mode recovers automatically after the fault condition is removed
Short Circuit: Hiccup mode, recovers automatically after the fault condition is removed
Over Voltage: 28 ~ 29.5V Shut down and latch off o/p voltage, re-power on to recover
Over Temperature: Shut down o/p voltage, re-power on to recover
Environment:
Working Temp.: Tcase=-40 ~ +40℃
Max. Case Temp.: Tcase=+85℃
Working Humidity: 20 ~ 95% RH non-condensing
Storage Temp., Humidity: -40 ~ +80℃, 10 ~ 95% RH
Temp. Coefficient: ±0.03%/℃ (0 ~ 50℃)
Safety & EMC:
Safety Standards: EN61347-1, BS EN/EN61347-2-13 independent, EN62384, GB19510.1,GB19510.14,EAC TP TC 004,IP67 approved; Design refer to EN60335-1
Withstand Voltage: I/P-O/P:3.75KVAC
Isolation Resistance: I/P-O/P:100M Ohms / 500VDC / 25℃/ 70% RH
EMC Emission: Compliance to BS EN/EN55015, BS EN/EN61000-3-2 Class C (@load≧60%) ; BS EN/EN61000-3-3; GB17743 and GB17625.1,EAC TP TC 020
EMC Immunity: Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11; BS EN/EN61547, light industry level (surge immunity Line-Line 2KV); EAC TP TC 020
Others:
Dimension: 226*67*40mm (L*W*H)
Packing: 0.77Kg
TILLUME HLG-100W-24A LED Power Supply Test Report
1, Block Diagram
2, Performance Evaluation
This session presents the test results of HLG-100W-24A LED Power Supply up to date. Overall the power supply meets the design specification.
All data was measured at 1.5M AWG16 CABLE END
Performance Highlights
- No load standby power: below 40mW @230V
- Max Efficiency @ 100% Load: 90.00%@115VAC & 91.20%@230VAC
Characterization Results Summary
Test Item |
Test Result |
1.Input Characteristics | |
Standby Power at no Load | 22mW |
Average Efficiency( 230Vac, 100% Load) | 91.20% |
2. Output Characteristics | |
Line regulation | 0.5% |
Load regulation | 1.5% |
Ripple & Noise | 100mV |
Over Shoot | 2.6% Max |
Under Shoot | 2.2% Max |
Dynamic test | ±360mV |
3. Time Sequence | |
Set up time | <350mS |
Hold up time | >25mS |
Rise time | <150mS |
Fall time | <15ms |
Test Equipments
Item | Brand | Module |
AC Source | EVERFINE | DPS1005-V200 |
Digital Power Meter | EVERFINE | LT-101A |
Electrical Load | ITECH | IT8512G+ |
Oscilloscope | Tektronix | MDO32 |
Thermal | HIKVISION | K20 |
2,1 Input Characteristics
2,1,1 Standby Power / PF / THD
Table.1 Standby Power Without Load
Input Voltage | Specification | Standby Power(mW) | Vo(V) |
100Vac/60Hz | 150mW | 20mW | 24.2 |
115Vac/60Hz | 20mW | 24.2 | |
230Vac/50Hz | 30mW | 24.2 | |
264Vac/50Hz | 50mW | 24.2 |
Table.2 PF and THD with Full load
Input Voltage | Specification | PF | Specification | THD(%) |
100Vac/60Hz | >0.95 | 0.99 | <20% | 9.3% |
115Vac/60Hz | 0.99 | 8.8% | ||
230Vac/50Hz | 0.97 | 12.4% | ||
264Vac/50Hz | 0.96 | 13.2% |
2,1,2 Efficiency
Table.3 Efficiency
Input Voltage | 100% | 75% | 50% | 25% | Avg. Eff |
115Vac/60Hz | 90.0% | 90.8% | 90.2% | 90.5% | 90.37% |
230Vac/50Hz | 91.2% | 90.5% | 90.8% | 90.5% | 90.75% |
2,2 Output Characteristics
2,2,1 Line Regulation @ Load Regulation
Table.4 Line Regulation@l Load Regulation
Input Voltage | No Load | Half Load | Full Load | Specification |
100Vac/60Hz | 24.2V | 24.1V | 24.0V | |
115Vac/60Hz | 24.2V | 24.1V | 24.0V | |
230Vac/50Hz | 24.2V | 24.1V | 24.0V | |
264Vac/50Hz | 24.2V | 24.1V | 24.0V | |
Line Regulation | 0% | 0.5% | ||
Load Regulation | 0.82% | 1.5% |
2,2,2 Ripple & Noise
Table.5 Ripple & Noise
Input Voltage | R&N (mV) | ||
No Load | Full Load | Specification | |
100Vac/60Hz | 23mV | 87mV | 100mV |
115Vac/60Hz | 23mV | 72mV | |
230Vac/50Hz | 22mV | 46mV | |
264Vac/50Hz | 22mV | 46mV |
2,2,3 Dynamic Test
The Dynamic Test with a low set at 10% load lasting for 10ms and high set at 100% load lasting for 10ms is added to the output. The ramp is set at 0.25A/us at transient.
Table.6 Dynamic Test
Input Voltage
|
Output(mV) | Specification |
100Vac/60Hz | ||
115Vac/60Hz | ||
230Vac/50Hz | ||
264Vac/50Hz |
2,2,4 Time Sequence (Full load)
Table.7 Time Sequence
Item | Input voltage | Meas.Data | Specification |
Set up time | 230V/115V | 73.6mS/340mS | <500mS |
Hold-up time | 230V/115V | 25.6mS/25.2mS | >10mS |
Rise Time | 230V/115V | 104.5mS/136.3ms | <150mS |
Fall Time | 230V/115V | 11.1mS/11.8mS | NA |
2,3 Temperature Test
Table.8 TemperatureTest
The thermal test is under 30℃ ambiance after 4 hours full load runing with 230Vac input
Position | Mark | Description | Value |
BD1 | P1 | Bridge | 64.7℃ |
Q1 | P2 | PFC MOS | 65℃ |
Q2 | P3 | QR MOS | 67.5℃ |
D1 | P4 | Didoe | 66.1℃ |
T1 | P5 | PFC Transformer | 50.3℃ |
CAP1 | P6 | Capacitor | 51.1℃ |
T2 | P7 | QR Transformer | 91℃ |
Q3 | P8 | Synchronous MOS | 77℃ |
CAP2 |
P9 | Capacitor | 61.3℃ |
CAP3 | P10 | Capacitor | 56.3℃ |
3, Protection Performance
3,1 Over Current Protection
Input Voltage | OCP Trigger Current (A) | Specification |
100Vac/60Hz | 5A | 5A |
115Vac/60Hz | 5A | |
230Vac/50Hz | 5.4A | |
264Vac/50Hz | 5.4A |
3,2 Over Voltage Protection
Input Voltage | Output OVP Trigger Voltage (V) |
115Vac/60Hz | 29.5V |
230Vac/50Hz | 29.3V |