24V LED spots for smart lighting projects

24V LED Spots: Tunable White, RGBW and dimmable modules

Choose 24V LED spots by the way the room should behave in a smart-lighting system. TILLUME spot modules are built for KNX, DALI, Loxone and premium 24V projects, with attention to PWM dimming, voltage-drop tolerance, light quality and future replacement.

Use Tunable White for warm-to-cool white scenes, RGBW or RGBWW for color and accent lighting, and dimmable Single CCT when the color temperature should stay fixed.

1

Closer color consistency: LEDs are produced to SDCM <3 first, then sorted into 3 BIN groups; one order is supplied from the same BIN group to keep visible color differences low.

2

More tolerance in 24V cabling: constant-current compensation helps the spot handle real low-voltage cable runs more consistently.

3

Modular replacement: GU10/MR16-compatible module format supports easier maintenance and project expansion.

4

One 24V system: spot modules, controllers and 24V power supplies are selected around the same smart-lighting setup.

Browse the products below first, or open the planning guide if you need a full 24V system overview.

Sort by:
4500K LED Spot 24V Module | 60°, 6W CRI90, MR16 Retrofits - TILLUME

4500K LED Spot Warm White | 60°, 6W CRI90, 24V DC, MR16 Retrofits

€11,29 EUR
Static CCT 4500K 24V LED Spot Module Feature The TILLUME 24V LED Spot Module is the perfect solution for all applications that require a clearly aligned and yet homogeneous light pattern.Be...
Tunable White LED Spot | 60° Ra90 2400-4000K 24V 8W+8W

Tunable White LED Spot | 60° Ra90 2400-4000K 24V 8W+8W

€28,34 EUR
Deep Tunable White LED Spots  2400-4000K  | 8W+8W Wattage Balance Feature Human-perceived natural white tones are aligned along a distinctively curved trajectory in the chromaticity space – the Planckian Locus...
Full Spectrum LED Spot Tunable White | 60°  CRI95 2400-4000K 24V 6W+6W

Full Spectrum LED Spot Tunable White | 60° CRI95 2400-4000K 24V 6W+6W

€31,49 EUR
Eye Safe High CRI Sunlight | Full Spectrum  Ra95 24V Tunable White LED Spots 2400-4000K | 6W+6W Wattage Balance controllable with DALI DT8 or Balance Dimmer Feature Human-perceived natural white tones...
Tunable White LED Spot | 60° Ra90 2400-4000K 24V 6W+6W

Tunable White LED Spot | 60° Ra90 2400-4000K 24V 6W+6W

€24,04 EUR
Deep Tunable White LED Spots  2400-4000K  | 6W+6W Wattage Balance Feature Human-perceived natural white tones are aligned along a distinctively curved trajectory in the chromaticity space – the Planckian Locus...
Full Spectrum LED Spot Tunable White | 60°  CRI95 2200-6500K 24V 6W+6W

Full Spectrum LED Spot Tunable White | 60° CRI95 2200-6500K 24V 6W+6W

€31,49 EUR
Eye Safe High CRI Sunlight | Full Spectrum  Ra95 24V Tunable White LED Spots 2200-6500K | 6W+6W Wattage Balance controllable with DALI DT8 or Balance Dimmer Feature TILLUME tunable white LED...
4500K LED Spot Warm White | 60°, 8W CRI90, 24V DC, MR16 Retrofits - TILLUME

4500K LED Spot Warm White | 60°, 8W CRI90, 24V DC, MR16 Retrofits

€13,49 EUR
Static White 4500K 24V LED Spot Module Feature The TILLUME 24V LED Spot Module is the perfect solution for all applications that require a clearly aligned and yet homogeneous light...

Selection guide for 24V LED spot modules

How to choose 24V LED spots for your project

Start by choosing the lighting behavior your room or project needs. TILLUME 24V LED spot modules cover three main directions: Tunable White for CCT scenes, RGBW or RGBWW for color and accent lighting, and dimmable Single CCT for fixed-white rooms where smooth PWM dimming is the priority.

In DALI, KNX, Loxone or similar projects, the spot module and the final 24V PWM output need to work together. The protocol controls the controller or actuator; the LED side still needs the right output voltage, channel mapping, power supply and cable design.

Quick selector: which 24V LED spot type fits your use case?

Project intent Recommended spot type Planning notes
Warm-to-cool white scenes Tunable White 24V LED spots Use 2200-6500K for wide HCL schedules or 2400-4000K for Dim to Warm scenes where middle-CCT pinkish tint is a concern. Requires two 24V PWM channels.
Color scenes and accent light RGBW / RGBWW 24V LED spots Use for decorative color, accent zones and mixed white/color scenes. Check channel count, controller mode and RGBW/RGBWW mapping before ordering.
Fixed white with smooth dimming Dimmable Single CCT spots Choose 2850K, 3300K or 4000K by room atmosphere and task. Use a suitable 24V PWM dimmer or actuator for 1-100% dimming behavior.
DALI, KNX or Loxone projects 24V spots + matching PWM controller DALI, KNX or Loxone controls the controller or actuator. The LED-side output must match voltage, channels, PWM frequency and dimming logic.
Ceiling, recessed or surface-mounted installation Spot module + housing or frame Select the LED module and visible fitting together. Check cut-out size, installation depth, heat space and finish before installation.
warm cool

01 Tunable White

For CCT scenes, DTW and HCL

Choose Tunable White when the room needs controllable warm-to-cool white light. Typical use cases include living areas, kitchens, bedrooms, offices and DALI DT8 / KNX / Loxone scenes that combine brightness and color temperature.

View Tunable White collection →
color white

02 RGBW / RGBWW

For color, accent and atmosphere

Choose RGBW or RGBWW modules for color scenes, accent lighting and decorative zones. RGBW is not a replacement for every general-lighting task; use it when the project really needs color channels plus a white channel.

View RGBW collection →
dim bright

03 Dimmable Single CCT

For stable fixed-white rooms

Choose Single CCT spots when the color temperature should stay constant and the user mainly needs smooth brightness control. Use 2850K for warm residential atmosphere, 3300K for balanced warm-neutral light and 4000K for more neutral task areas.

View dimmable collection →

Expert vs Master: choose by light-quality demand

First choose the control function: Tunable White, RGBW/RGBWW or Single CCT. Then choose Expert or Master by the light quality the room actually needs. Master is useful when red rendering, material appearance or smoother spectrum behavior matters; it is not automatically the right choice for every room.

Decision point Expert Series Master Series
Typical use General residential and project lighting where Ra90 is enough Premium interiors, kitchens, dining areas, studios, display zones and material-sensitive rooms
CRI / Ra level Ra90 Ra95
R9 red rendering Product- and CCT-specific; check the test report before specification Single CCT Master: R9 >=92; 2850K R9 = 92, 4000K up to R9 94
Voltage-drop planning Minimum input voltage 21.5V Minimum input voltage 23V; practical tolerance can be close in many installations when the 24V DC supply is set to about 24.5V

Planning note: keep the spot-side voltage around 24V and normally no higher than about 24.5V. Voltage-drop tolerance helps, but it does not replace proper cable and power-supply planning.

Complete your 24V LED spot system

A good 24V smart-lighting result depends on more than the spot module. Plan the LED module, housing, controller, 24V DC power supply, cable route and dimming logic together, so the KNX, DALI or Loxone setup produces the light quality you expect.

Frequently asked questions

QHow should I match a 24V LED spot with DALI, KNX or Loxone?

Plan the spot module and the final 24V PWM output together. DALI, KNX or Loxone handles the upper-level control logic, but the LED-side output still needs to match the spot type, channel count, load capacity, PWM frequency and dimming curve.

QWhat matters more in a 24V spot system: protocol, controller or LED-side output?

The protocol is only one part of the system. The final 24V PWM controller or actuator often decides low-end dimming quality, Tunable White mixing, RGBW channel behavior and usable load per channel.

QHow should voltage drop be planned for TILLUME 24V LED spots?

Start with cable length, conductor cross-section, channel load and power-supply position. TILLUME spot modules tolerate real 24V constant-voltage cabling better than simple LED loads, but cable planning still matters. For long-term lifetime, keep the spot-side voltage around 24V and normally no higher than about 24.5V.

QWhen is Ra95 Master worth choosing over Ra90 Expert?

Choose Master for rooms where red rendering, skin tones, wood, food, textiles or artwork are easy to notice. Expert is enough for many residential and project areas; Master makes sense when material appearance matters more than simply reaching Ra90.

QHow do I avoid visible color differences between multiple spot modules?

Use modules from the same order and avoid mixing different batches in the same visible lighting zone. TILLUME LEDs are produced to SDCM <3 first, then sorted into 3 BIN groups; one order is supplied from the same BIN group to keep visible color differences low.

QShould Tunable White be specified by CCT range or by control behavior?

Both matter. Use 2200-6500K for wide HCL or daylight-style schedules. Use 2400-4000K when the priority is cleaner Dim to Warm behavior with less pinkish middle-CCT impression. Also check whether the controller uses two PWM channels, DALI DT8 logic or another mapping method.

Planning guides

Further reading for 24V LED spot planning

Use these guides before ordering if you need to check CCT, CRI, dimming, voltage drop or DALI/KNX/Loxone control.

Build the complete 24V LED spot setup

Start with the spot type: Tunable White, RGBW/RGBWW or dimmable Single CCT. Then match the module with the correct 24V PWM controller, 24V DC power supply, housing or frame, cable route and channel planning.